Memory Channel

Supported by...

All PixeLINK Cameras

Description

The memory channel feature stores all camera parameters into non-volatile memory.  It is similar to camera configuration files used in frame grabbers and some software packages such as LabVIEW but here the file resides with the camera, not the host PC.

The on-board memory allows the camera to be configured on one computer and used on another without the need to transfer camera configuration files or other configuration data.  For example, the camera could be set up to provide a 648 x 480 field of view at 88 frames per second with a particular exposure, gamma and white balance settings and these settings programmed into the camera memory.  The next time the camera is initialized, on any PC, it will default to these settings.  This is especially useful for software packages that have limited camera control capabilities.  The camera can be configured with PixeLINK software and used in that configuration by a third party application.

The camera memory can also be used to establish a known state for an automatic control process.  At the start of the process, the camera parameters can be reset to those in camera memory without the need to set all parameters in software.

Valid values are 0 for factory defaults or 1 for memory channel 1. During power-up, the camera will always load the configuration parameters stored in Memory Channel 1.  When the camera is delivered from the factory, the configuration in Memory Channel 1 matches the factory defaults in Memory Channel 0. 

The user can always restore the user settings to the factory defaults as follows:

API Control

The memory channel is saved with the API function PxLSaveSettings and is applied with the API function PxLLoadSettings.

Read with PxLGetCameraFeatures to determine MAX_MEMORY_CHANNEL.

Feature

Number of Parms

Parameters

Units

Restrictions

FEATURE_MEMORY_CHANNEL 

The memory channel to which the settings can be saved

1

fValue

N/A

Integer only

 

Feature Flags

Camera

Presence

Read Only

Auto

Manual

One-time Auto

Off

CiD

All cameras

Yes

No

No

Yes

No

No

No

Parameters

Parameter

Unit

Type

Min

Max

Default

Step Size

Comments

fValue

None

Absolute

0

1

0

1

Memory channel 0

IIDC Control

There is no access to this feature through the IIDC control methods